Testo 440 delta P Air Flow ComboKit 1 with Bluetooth®

  • Intuitive: clearly structured measurement menu for volume flow and parallel determination of air velocity, differential pressure, humidity and temperature in ventilation ducts or at ventilation outlets
  • Space-saving: simply combine the universal Bluetooth handle with the 100 mm vane or hot wire probe head and the extendable telescope (1.0 m)
  • Convenient: wireless probes, internal data storage and USB port for data export
  • As multifaceted as your challenges themselves: the testo 440 dP has an integrated differential pressure sensor and can be expanded with a large portfolio of digital probes

Details

Product Description

Carry out measurements without any annoying cables: use the kit to handle all relevant measurements in ventilation ducts and at air/ceiling outlets.
You will receive the testo 440 dP air velocity and IAQ measuring instrument including differential pressure sensor and the 100 mm vane probe head and hot wire probe head (Ø 9 mm) for attachment to the universal Bluetooth® handle supplied.
To make measurements more convenient, both probe heads can be combined with the telescope included in the kit. The equipment can be transported safely and conveniently in the robust case.

Delivery Scope

  • testo 440 dP air velocity and IAQ measuring instrument including differential pressure sensor, connection hose, 3 x AA batteries, USB cable and calibration protocol (0560 4402)
  • Vane probe (Ø 100 mm) with Bluetooth® including temperature sensor (consisting of 100 mm vane probe head, handle adapter and Bluetooth® handle); bracket for testovent measurement funnel; 4 x AA batteries and calibration protocol (0635 9431)
  • Hot wire probe head (Ø 9 mm) including temperature and humidity sensor and calibration protocol (0635 1570)
  • Extendable telescope (up to 1 m in length) for air velocity probes with a universal handle including 90° angle (0554 0960)
  • Combi-case for testo 440 and multiple probes (0516 4401)

Technical Data

testo 440 dP – Air velocity and IAQ measuring instrument including differential pressure sensor

Temperature – NTC

Measuring range -40 to +150 °C
Accuracy ±0.4 °C (-40 to -25.1 °C)

±0.3 °C (-25 to +74.9 °C)

±0.4 °C (+75 to +99.9 °C)

±0.5 % of mv (Remaining Range)

Resolution 0.1 °C

Temperature – TC Type K (NiCr-Ni)

Measuring range -200 to +1370 °C
Accuracy ±(0.3 °C + 0.3 % of mv)
Resolution 0.1 °C

Differential pressure (internal sensor) – Piezoresistive

Measuring range -150 to +150 hPa
Accuracy ±0.05 hPa (0 to 1.00 hPa)

±0.2 hPa + 1.5 % of mv

(1.01 to +150 hPa)

Resolution 0.01 hPa

General technical data

Weight 250 g
Dimensions 154 x 65 x 32 mm
Operating temperature -20 to +50 °C
Product colour black/orange
Connectable probes 1 x digital probe with cable or 1 x Temperature NTC TUC, 1 x digital Bluetooth probe or testo Smart Probe, 1 x differential pressure (internal), 1 x Temperature TC Type K
Battery type 3 AA mignon 1.5 V
Battery life 12 h (typically vane measurement)
Interface Bluetooth®; USB
Storage temperature -20 to +50 °C

Vane probe (Ø 100 mm, digital) – with Bluetooth® including temperature sensor

Temperature – NTC

Measuring range -20 to +70 °C
Accuracy ±0.5 °C
Resolution 0.1 °C

 

Velocity / Volume flow

Measuring range 0.3 to 35 m/s
Accuracy ±(0.1 m/s + 1.5 % of mv) (0.3 to 20 m/s)

±(0.2 m/s + 1.5 % of mv) (20.01 to 35 m/s)

Resolution 0.01 m/s

 

General technical data

Storage temperature -20 to +60 °C
Weight 360 g
Dimensions 375 x 105 x 46 mm
Operating temperature -5 to +50 °C
Probe head diameter 100 mm
Product colour black/orange
Battery type 4 x type AA batteries
Battery life 60 h
Data transfer Bluetooth®
Radio range 20 m

 

Hot wire probe (digital) – including temperature sensor, wired

Temperature – NTC

Measuring range -20 to +70 °C
Accuracy ±0.5 °C
Resolution 0.1 °C

 

Absolute Pressure

Measuring range +700 to +1100 hPa
Accuracy ±3.0 hPa
Resolution 0.1 hPa

 

Velocity – Hot wire

Measuring range 0 to 30 m/s
Accuracy ±(0.03 m/s + 4 % of mv)

(0 to 20 m/s)

±(0.5 m/s + 5 % of mv)

(20.01 to 30 m/s)

Resolution 0.01 m/s

 

General technical data

Storage temperature -20 to +70 °C
Weight 90 g
Dimensions 315 x 12 x 12 mm
Operating temperature -20 to +70 °C
Cable length 1.7 m
Length telescope 850 mm
Probe head diameter 9 mm
Diameter telescope 12 mm
Product colour Black; silver
Diameter probe shaft 12 mm

Extendable telescope (up to 1 m in length) for flow probes

General technical data

Weight 155 g
Dimensions telescope: 375 x 17 x 16 mm

angle: 65 x 65 x 15 mm

Operating temperature -5 to +50 °C
Length telescope 1,000 mm
Diameter telescope 12 mm
Product colour Black
Storage temperature -20 to +60 °C

Combi-case for testo 440 and multiple probes

General technical data

Weight 1400 g
Dimensions 516 x 135 x 256 mm
Product colour Black

 

Downloads

Product Brochures

Data sheet testo 440 (application/pdf, 3.365 KB)

Data sheet testo 440 delta P Air Flow ComboKit 1 with Bluetooth® (application/pdf, 598 KB)

Manuals

Instruction manual testo 440 (application/pdf, 1.989 KB)

Instruction manual testo Air velocity and IAQ probes with Bluetooth® handle (application/pdf, 877 KB)

Product Enquiry

Error: Contact form not found.