Details
Product Description
Delivery Scope
Please note that your testo 340 must be fitted with a second gas sensor for it to work. Up to three additional sensors can be fitted.
Emission checks in industry are easy with the flue gas analyzer testo 340. Professional technology meets practical design. The testo 340 flue gas analyzer is easy-to-use for emission measurement in industries. It can be fitted with up to four different gas sensors.
Measuring range | -200 to 200 hPa |
Accuracy | ±0.5 hPa (-49.9 to 49.9 hPa)
±1.5 % of mv (Remaining Range) |
Resolution | 0.1 hPa |
Measuring range | +600 to +1150 hPa |
Accuracy | ±10 hPa |
Resolution | 1 hPa |
Measuring range | 0 to 25 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.01 Vol.% |
Reaction time t₉₀ | < 20 s |
Measuring range | 0 to 10000 ppm |
Accuracy | ±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 10000 ppm) |
Resolution | 1 ppm |
Reaction time t₉₀ | < 40 s |
Measuring range | 0 to 500 ppm |
Accuracy | ±2 ppm (0 to 39.9 ppm)
±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K. |
Resolution | 0.1 ppm |
Reaction time t₉₀ | < 40 s |
Measuring range | 0 to 4000 ppm |
Accuracy | ±5 ppm (0 to 99 ppm)
±5 % of mv (100 to 1999 ppm) ±10 % of mv (2000 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time t₉₀ | < 30 s |
Measuring range | 0 to 300 ppm |
Accuracy | ±2 ppm (0 to 39.9 ppm)
±5 % of mv (Remaining Range) |
Resolution | 0.1 ppm |
Reaction time t₉₀ | < 30 s |
Measuring range | 0 to 500 ppm |
Accuracy | ±10 ppm (0 to 199 ppm)
±5 % of mv (Remaining Range) |
Resolution | 0.1 ppm |
Reaction time t₉₀ | < 40 s |
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
Measuring range | 0 to 5000 ppm |
Accuracy | ±10 ppm (0 to 99 ppm)
±10 % of mv (Remaining Range) |
Resolution | 1 ppm |
Reaction time t₉₀ | < 40 s |
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
Measuring range | -40 to +40 hPa |
Accuracy | ±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of mv (Remaining Range) |
Resolution | 0.01 hPa |
Measuring range | -40 to +1200 °C |
Accuracy | ±0.5 °C (0 to +99 °C)
±0.5 % of mv (Remaining Range) |
Resolution | 0.1 °C |
Measuring range | 0 to 120 % |
Resolution | 0.1 % |
Measuring range | 0 to 99.9 % |
Resolution | 0.1 % |
Measuring range | 0 to 99.9 °Ctd |
Resolution | 0.1 °Ctd |
Measuring range | 0 to CO₂ max |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | < 40 s |
Weight | 960 g |
Dimensions | 283 x 103 x 65 mm |
Operating temperature | -5 to +50 °C |
Product-/housing material | TPE PC |
Protection class | IP40 |
Product colour | Black |
Connectable probes | 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure |
Battery life | > 6h (Pumpe an, Displaybeleuchtung aus, bei 20°C) |
Display type | graphic Display |
Display size | 160 x 240 pixels |
Display function | Graphic display |
Power supply | Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A |
Max. neg. press./flue gas | -200 mbar |
Max. pos. press./flue gas | 50 mbar |
User defined fuels | 10 user-defined fuels incl. test gas as fuel |
Hose length | max. 7.8 m (corresponds to two probe hose extensions) |
Pump flow | 0.6 l/min (regulated) |
Maximum memory | 100 folders |
Storage per folder | Max. 10 sites |
Storage per site | Max. 200 logs |
Miscellaneous | The max. number of logs is determined by the number of folders or sites |
Interface | Bluetooth®; USB; IR/IRDA interface; gas outlet; Mains connection; probe input/ probe inputs; Differential Pressure |
Storage temperature | -20 to +50 °C |