Testo 176 T3 – Data logger for temperature measurement

  • Ideal for long-term measurements: memory for up to 2 million readings, up to 8 years’ battery life
  • 4 inputs for optional thermocouple probes (temperature probes TC Type K, Type T, Type J)
  • Industrial standard thanks to robust metal housing and protection class IP 65
  • Three software versions are available for data analysis on the PC, basic software is free to download

The testo 176 T3 data logger for temperature measurement is ideal for monitoring temperature values in production processes. Its robust metal housing makes it ideal for use in the industrial sector. With inputs for four thermocouple probes, it can measure at up to four points in parallel.

This meter uses a sensor to start up, For these sensors (For filters) Check the probes section 

 

Details

Product Description

The data logger for temperature measurement – testo 176 T3 features a robust metal housing which makes it suitable for use in the industrial and trade sector,e.g. for process monitoring. You can measure the temperature at up to four points simultaneously – e.g. to measure the flow and return temperatures on radiators. Up to four thermocouple probes can be connected to the data logger (temperature probes TC Type K, Type T or Type J).You can select the thermocouple probes from our large probes range and order them when purchasing the data logger.

 

Advantages of Testo 176 T3 – Data logger for temperature measurement

 

The advantage of thermocouple probes is that they react very quickly and cover a large measuring range.For example, you can record particularly low temperatures (as low as -195 °C) using a temperature probe TC Type K – depending on the model selected – or you can even carry out high temperature measurements (up to +1,000 °C).This enables you to take measurements in super freezers and also monitor high-temperature industrial processes.The data logger for temperature measurement – testo 176 T3 records up to 2 million readings and can therefore be used for long-term measurements, eliminating the need for the data logger to be read out overly frequently.The data logger has a battery life of up to 8 years, which also makes it a practical instrument for long-term measurements.Technical features and practical benefitsThe testo 176 T3 data logger for temperature measurement has a metal housing, so it is well-equipped for industrial applications. The housing of the data logger means that it is extremely robust and, in conformity with protection class IP 65, also protected against dust ingress and water jets.The data logger can therefore be used in polluted and dust-laden environments. When carrying out cleaning at the measuring location, you do not need to remove the data logger.

When using the data logger for temperature measurement, you can rely on a high level of data security.

Measurement data that you have saved will not be lost, even if the battery is spent and being replaced – which is something you can carry out yourself.

Possible areas of application for the data logger for temperature measurement

–  Monitoring and recording the temperature in deep-freezers or in cryogenic conditions
–  Monitoring and recording the flow and return temperature of heating systems
–  Monitoring and recording process temperatures
–  Measuring and documenting flow and return temperatures at the distributor of an underfloor heating system in order to ensure functional capability

Programming and analysis of the data logger for temperature measurement

In order to program and read your data logger and analyze your temperature measurement data, you need to use a software package. There are three software versions to choose from:

–  ComSoft Basic software – available free of charge (as a download) – is used for quick programming of the data logger and for easy data analysis

–  ComSoft Professional software – available to order subject to a fee – provides you with multiple options for detailed analysis of the measured temperature values

–  ComSoft CFR 21 Part 11 software – available to order subject to a fee – is ideal for use in the pharmaceutical industry with its special requirements according to CFR 21 Part 11

The data logger for temperature measurement is programmed and read out by means of a USB cable, which is not included in the delivery.

You can also use the cable to transmit the measurement data to your PC. You also have the option of using an SD card for this. You can order both when purchasing your data logger.

 

Delivery Scope

testo 176 T3 data logger for temperature measurement, including wall bracket, lock, battery and calibration protocol.

Technical Data

Temperature – TC Type K (NiCr-Ni)

Measuring range -200 to +1000 °C
Accuracy ±1 % of mv (-200 to -100.1 °C) ±1 Digit

±0.3 °C (-100 to +70 °C) ±1 Digit

±0.5 % of mv (+70.1 to +1000 °C) ±1 Digit

Resolution 0.1 °C

Temperature – TC Type T (Cu-CuNi)

Measuring range -200 to +400 °C
Accuracy ±1 % of mv (-200 to -100.1 °C) ±1 Digit

±0.3 °C (-100 to +70 °C) ±1 Digit

±0.5 % of mv (+70.1 to +400 °C) ±1 Digit

Resolution 0.1 °C

Temperature – TC Type J (Fe-CuNi)

Measuring range -100 to +750 °C
Accuracy ±0.3 °C (-100 to +70 °C) ±1 Digit

±0.5 % of mv (+70.1 to +750 °C) ±1 Digit

Resolution 0.1 °C

General technical data

Weight 430 g
Dimensions 103 x 63 x 33 mm
Operating temperature -20 to +70 °C
Product-/housing material Plastic
Protection class IP65
Channels 4 external
Connectable probes 4 x thermocouple (type T, K and J)
Product colour silver
Standards EU-guideline 2014/30/EU; 2011/65/EU
Measuring rate 1 s to 24 h; 2 s to 24 h (online measurement)
Battery type 1 x Lithium (TL-5903)
Battery life 8 years at 15 min. meas. rate, +25 °C
Interface mini usb, SD card slot
Memory 2,000,000 measuring values
Storage temperature -40 to +85 °C

Downloads

Product Brochures

Datasheet testo 176-T3/4 (application/pdf, 520 KB)

Manuals

Instruction manual testo 176 (PDF, 2.8 MB)

Product Enquiry

Error: Contact form not found.