Five Valve Manifold Direct Mounting – “H” Type
FLANGED INSTRUMENT AND PROCESS CONNECTION-DRAIN PORT ON ONE SIDE OPTIONAL TEST PORT AT BOTTOM
Designed for direct or remote mounting of differential pressure transmitters. For remote mounting two oval/kidney flanges are used for connecting process pipe to manifold block. These manifold block incorporate five valves, two main valve for process isolation valve for vent two valves for equalizing.
Dimensions shown above are for the standard 54 mm or 2 1/8 inch instrument connection Centre distance found in majority of instruments. The manifold is also available for instruments with other centre distances for instrument connections (as 55 mm, 56 mm and 57 mm) but dimensions shown will vary. Please consult us for these dimensions. |
|
Connections | Process : Flanged Instrument : Flanged Drain / Vent : 1/4” NPT (F) |
Test Pressure | @ 25° C Room Temperature Hydrostatic : Body – 620 Kg/cm2 Seat – 413 Kg/cm2 Pneumatic : Seat – 40 Kg/cm2 |
Gland packing | PTFE : Standard GRAPHOIL : Temperatures above 180°C |
Material | A 105, A 182 / A 479 Gr F 304SS, A 182 / A 479 Gr F316SS, Monel, Hastelloy |
Finish | CS : Zinc Plated and Dichromated; SS : Natural |
Mounting kit | Mounting bracket with U bolts and necessary kits for fitting on 2″NB stanchion pipe stand or wall mount. (to be ordered seperately) |
Option | Test Port on process side with plug. |
Accessory | Mounting Bolts – IS : 1364 – 1960 – 4 Nos Interface seal – PTFE / VITO ‘N’ – 2 Nos |