Coplanar Mounting Five Valve Manifold

Designed as a new series of process instrument manifold for particular transmitter models. The coplanar manifold when assembled to transmitter has the advantage of compact size with ease for operation in minimum space, thereby eliminating several components in integrating the manifold to the transmitter. The coplanar manifold has two isolating valves, one equalizer valve and two vent valves and two bottom test ports duly plugged. The manifold dimensions illustrated are for standard 54 mm or 2 1/8 inch instrument centres but available for other centres. The direct mounting facility to the base of the differential pressure transmitter results in lesser leakage points and more accurate measurements.
Connections Process       : 1/2” NPT (F)
Instrument  : Flanged
Drain / Vent : 1/4” NPT (F)
Test Pressure @ 25° C Room Temperature
Hydrostatic   : Body – 620 Kg/cm2
Seat – 413 Kg/cm2
Pneumatic    : Seat – 40 Kg/cm2
Gland packing PTFE : Standard
GRAPHOIL : Temperatures above 180°C
Material A 105, A 182 / A 479 Gr F 304SS, A 182 / A 479 Gr F316SS, Monel, Hastelloy
Finish CS : Zinc Plated and Dichromated; SS : Natural
Option Test Port on process side with plug.
Accessory Mounting Bolts – IS : 1364 – 1960 – 4 Nos

Description