Four Valve Manifold – Double Isolate/Equalize/Vent Block – Direct Mounting Type

Designed for general liquid and gas measurement applications for differential pressure instruments with a common drain

The essential feature of this design is a vent/drain valve which is provided with a tamper proof handle to be removed after operation. This arrangement is especially suitable for applications with hazardous Fluid Controls.

Isolation valve with ‘T’ bar handle vent valve with anti tamper handle

Connections Process       : 1/4″NPT (F) / 1/4″ BSPT (F) / 10 mm OD
Instrument  : Flanged
Drain          : 1/4″NPT (F) / 1/4″ BSPT (F) / 10 mm OD
Test Pressure @ 25° C Room Temperature
Hydrostatic   : Body – 620 Kg/cm2
Seat – 413 Kg/cm2
Pneumatic    : Seat – 40 Kg/cm2
Gland packing PTFE : Standard
GRAPHOIL : Temperatures above 180°C
Material A 105, A 182 Gr F 304SS, A 182 Gr F 316SS, Monel, Hastelloy
Finish CS : Zinc Plated and Dichromated; SS : Natural
Accessory Mounting Bolts – IS : 1364 – 1960 – 4 Nos
Interface seal – PTFE / VITO ‘N’ – 2 Nos

Description